API browser of generalFormRequest450 COM module


/images/arrow_right.png IGeneralFormRequest::AddTextResult method space
Adds a textual result structure to the list of textual result structures.

Such a result structure can be from the clinical as well as from the lab area but is inherently of textual nature.

space
/images/arrow_right.png Restful webservice calling syntax
[POST] /baseURL/IGeneralFormRequest/AddTextResult
[JSON input data] pIGeneralFormRequest:
bstrStructName:
eResultCodeType:
bstrCode:
bstrName:
dDate:
bstrValue:
bstrReference:
bstrRemark:
longValue,    //interface address
"utf8StringValue",
longValue,
"utf8StringValue",
"utf8StringValue",
variantDateValue | "stringISODateValue",
"utf8StringValue",
"utf8StringValue",
"utf8StringValue"
[JSON result data] pbStatus: booleanValue
 
[HTTP result status] 200 Return status 200 signals a successful method call
204 Return status 204 (noContent) signals that the end of an iteration is reached
>= 400 Return status >= 400 signals an unsuccessful function call. The returned JSON{errorCode: code, errorText:"text"} supplies the error message the same as GetAbortInfo() would do.
space
/images/arrow_right.png C/C++ calling syntax
HRESULT AddTextResult( BSTR
ResultCodeType
BSTR
BSTR
DATE
BSTR
BSTR
BSTR
VARIANT_BOOL
bstrStructName,
eResultCodeType,
bstrCode,
bstrName,
dDate,
bstrValue,
bstrReference,
bstrRemark,
*pbStatus);
[C/C++ return value] S_OK This value is returned if the function call was successful.
S_FALSE This value is returned if the end of an iteration is reached
E_name This value is returned if the function call was unsuccessful and an error exception was generated. Note that if you are using SmartPointers an exception is thrown under these conditions.
space
/images/arrow_right.png Calling argument description
[in] BSTR bstrStructName The variable name/placeholder of the structure.

Use the iterator pair GetFirstStructRole / GetNextStructRole to retrieve the variable name, the semantical typification and the status (defined or undefined) of all structures defined by the currently load PDF form.

[in] ResultCodeType eResultCodeType The used coding system in which the result is defined.
[in] BSTR bstrCode The code of the measurement defined in the used coding system.

While not imperative the preferable coding system for lab results is LOINC and SMERF for clinical results. Especially for lab results LOINC is the only guarantee that identifies lab measurements unambiguously and lab company independent.

[in] BSTR bstrName The name of the measurement.
[in] DATE dDate The date of the measurement.
[in] BSTR bstrValue The textual value of the measurement.
[in] BSTR bstrReference An optional reference of any kind that further qualifies the given result value.
[in] BSTR bstrRemark An optional remark
[out,retval] VARIANT_BOOL *pbStatus Return status of the method. If pbStatus is VARIANT_FALSE then an error occurred and GetAbortInfo should be called to retrieve the error string.
space